Manual Synchronization
The admin redundancy synchronize command performs manual CPM synchronizations.
The boot-env parameter synchronizes the BOF, image, and configuration files in redundant
systems. The config parameter synchronizes only the configuration files in redundant
systems.
Forcing a Switchover
The force-switchover now command forces an immediate switchover to the standby CPM
card.
If the active and standby are not synchronized for some reason, users can manually
synchronize the standby CPM by rebooting the standby by issuing the admin reboot standby
command on the active or the standby CPM.
System Configuration Process Overview
Figure 27 displays the process to provision basic system parameters.