System Management
Basic System Configuration Guide 363
rmon-event-type Specifies the type of notification action to be taken when this event occurs.
Values log — An entry is made in the RMON-MIB log table for each
event occurrence. This does not create a TiMOS logger entry. The
RMON-MIB log table entries can be viewed using the
show>system>thresholds CLI command.
trap — A TiMOS logger event is generated. The TiMOS logger
utility then distributes the notification of this event to its
configured log destinations, which may be CONSOLE, telnet
session, memory log, cflash file, syslog, or SNMP trap
destinations logs.
both — Both an entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — No action is taken.
Default both
alarm-typeSpecifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is
equal to falling or either, a single falling threshold crossing event is generated.
Values rising, falling, either
Default either
Configuration example
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900
interval 120 rmon-event-type both start-alarm rising
cflash-cap-alarm-pct
Syntax cflash-cap-alarm-pct cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm-pct cflash-id
Context config>system>thresholds
Description This command enables capacity monitoring of the compact flash specified in this command. The usage
is monitored as a percentage of the capacity of the compact flash. The severity level is alarm. Both a
rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
Values cf1:, cf1-A:, cf1-B:, cf2:, cf2-A:, cf2-B:, cf3:, cf3-A:, cf3-B: