Basic System Configuration Guide 371
interval secondsSpecifies the polling period over which the data is sampled and compared
with the rising and falling thresholds.
Values 1 to 2147483647
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
Values log — In the case of log, an entry is made in the RMON-MIB log
table for each event occurrence. This does not create a TiMOS
logger entry. The RMON-MIB log table entries can be viewed
using the show>system>thresholds CLI command.
Values trap — In the case of trap, a TiMOS logger event is generated.
The TiMOS logger utility then distributes the notification of this
event to its configured log destinations which may be CONSOLE,
telnet session, memory log, cflash file, syslog, or SNMP trap
destinations logs.
Values both — In the case of both, both a entry in the RMON-MIB
logTable and a TiMOS logger event are generated.
Values none — In the case of none, no action is taken.
Default both
startup-alarm alarm-typeSpecifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, then a single rising threshold crossing event is generated. If the first
sample is less than or equal to the falling threshold value and startup-alarm is equal to falling
or either, a single falling threshold crossing event is generated.
Values rising, falling, either
Default either
event
Syntax event rmon-event-id [event-type] [description description-string] [owner owner-string]
no event rmon-event-id
Context config>system>thresholds>rmon
Description The event command configures an entry in the RMON-MIB event table. The event command controls
the generation and notification of threshold crossing events configured with the alarm command.
When a threshold crossing event is triggered, the rmon>event configuration optionally specifies if an
entry in the RMON-MIB log table should be created to record the occurrence of the event. It may also
specify that an SNMP notification (trap) should be generated for the event. The RMON-MIB defines
two notifications for threshold crossing events: Rising Alarm and Falling Alarm.