532 Basic System Configuration Guide
Not Selected Due To : on standby
Source Port : 1/1/5
Reference Input 2
Admin Status : up
Rx Quality Level : prc
Quality Level Override : none
Qualified For Use : Yes
Selected For Use : No
Not Selected Due To : on standby
Source Port : 3/1/5
Reference BITS A
Input Admin Status : up
Rx Quality Level : prc
Quality Level Override : none
Qualified For Use : Yes
Selected For Use : No
Not Selected Due To : previous failure
Interface Type : E1
Framing : PCM31 CRC
Line Coding : HDB3
SSM Bit : 8
Output Admin Status : up
Output Source : line reference
Output Reference Selected : ref1
Tx Quality Level : prc
Reference BITS B
Input Admin Status : up
Rx Quality Level : prc
Quality Level Override : none
Qualified For Use : Yes
Selected For Use : Yes
Interface Type : E1
Framing : PCM31 CRC
Line Coding : HDB3
SSM Bit : 8
Output Admin Status : up
Output Source : line reference
Output Reference Selected : ref1
Tx Quality Level : prc
===============================================================================
The following system example shows:
sync-if timing standby, or
sync-if-timing “B” when the SETS reference on the standby CPM-B locks to Mate CPM
(BITS B), or
sync-if-timing “A” when the SETS reference on the standby CPM-A locks to Mate CPM
(BITS B)
Note: The following output applies only to the 7750 SR-1e/2e/3e and 7950 XRS-16/20/40 platforms.
--------------------------------------------------------------------
*A:Dut-B# show system sync-if-timing standby or show system sync-if-timing "B"
===============================================================================
System Interface Timing Operational Info