102    Sequoia Series 
PHASe:TRIGgered 
Phase Selectable 
This command sets the output phase when a triggered step or pulse transient occurs. The phase of 
the  output  voltage  waveform  is  expressed  relative  to  an  internal  reference.  The  phase  angle  is 
programmed in degrees. Positive phase angles are used to program the leading phase, and negative 
phase angles are used to program the lagging phase. 
The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current 
output phase selected by INSTrument:NSELect. 
Command Syntax  [SOURce:]PHASe:TRIGgered<NRf+> 
Parameters  -360° through +360° 
*RST Value  triggered phase ø1 = 0°, triggered 
  phase ø2 = 120°, triggered phase ø3 = 240° 
Examples  PHAS:TRIG 120  PHASE MAX 
Query Syntax  [SOURce:]PHASe:TRIGgered? 
Returned Parameters  <NR3> 
Related Commands  PHAS:MODE  PHAS