102 Sequoia Series
PHASe:TRIGgered
Phase Selectable
This command sets the output phase when a triggered step or pulse transient occurs. The phase of
the output voltage waveform is expressed relative to an internal reference. The phase angle is
programmed in degrees. Positive phase angles are used to program the leading phase, and negative
phase angles are used to program the lagging phase.
The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current
output phase selected by INSTrument:NSELect.
Command Syntax [SOURce:]PHASe:TRIGgered<NRf+>
Parameters -360° through +360°
*RST Value triggered phase ø1 = 0°, triggered
phase ø2 = 120°, triggered phase ø3 = 240°
Examples PHAS:TRIG 120 PHASE MAX
Query Syntax [SOURce:]PHASe:TRIGgered?
Returned Parameters <NR3>
Related Commands PHAS:MODE PHAS