84    Sequoia Series 
Command Syntax  [SOURce:]SYNChronize:FREQuency <NRf+> 
   
Parameters  16 to 550 Hz  
Unit  Hz 
Examples  SYNC:FREQ 50 
Query Syntax  [SOURce:]SYNChronize:FREQuency? 
Returned Parameters  <NR2>  
Related Commands  SYNC:FREQ?MIN, SYNC:FREQ?MAX 
[SOURce:]SYNChronize:PHASe 
Phase Selectable 
This command programs the sync phase level of the power source. 
Command Syntax  [SOURce:]SYNChronize:PHASe <NRf+> 
   
Parameters  -360 to +360 
Unit  deg 
Examples  SYNC:PHAS 240 
Query Syntax  [SOURce:]SYNChronize:PHAS? 
Returned Parameters  <NR2>  
Related Commands  SYNC:PHAS?MIN, SYNC:PHAS?MAX 
[SOURce:]SYNChronize:VOLTage 
Phase Selectable 
This command programs the sync voltage level of the power source. 
Command Syntax  [SOURce:]SYNChronize:VOLTage <NRf+> 
   
Parameters  <NRf+> 
Unit  V  
Examples  SYNC:VOLT 250 
Query Syntax  [SOURce:]SYNChronize:VOLTage? 
Returned Parameters  <NR2>  
Related Commands  SYNC:VOLT?MIN, SYNC:VOLT?MAX 
4.17  Source Subsystem – Program (eLoad Mode) 
This subsystem programs the Operating Mode settings of the Sequoia Series power source. 
Subsystem Syntax 
[SOURce:] 
  PROGram 
    [:MODE]?    Responds with current operating mode   
    :ELOAD       
      [:MODE]  Sets  the  different  SINK  eLoad  Operating 
mode