5.6 *OPT?
This query requests the power source to identify any options that are installed. Options are identified
by a string keyword or a number. A 0 anywhere in this list indicates that specific feature is not installed.
If a feature is installed or available, its corresponding keyword will be returned. Refer also to the
SYSTem:CONFigure[:BYTE] command. This command only has a query format as these settings
cannot be changed.
Query Syntax *OPT?
Returned Parameters <CRD>,[<CRD>]
The parameter list returned and their order in the sequence is shown in the table below.
Syntax
Description
Comment
SCPI
SCPI language
This feature is always enabled on Sequoia Series
models.
NOUT
MODE option
Phase mode selection. Available only on Sequoia 2U,
3-Phase systems.
ADV
Advanced Features
Available on Sequoia Series models with 3-Phase
controllers only.
CLK/LOC
Clock and Lock
mode
Allows multiple controllers to be synced.
DO160
Option 160
RTCA/DO160 test option.
MIL704D
Option 704
MIL-STD704 test option.
IEC411
Option -411
IEC61000-4-11 voltage dips and interruptions test
option. This option must be installed to support the
EOS1 or EOS3.
IEC413
Option -413
IEC61000-4-13 Interharmonics test option.
WHM
Option WHM
Supported only on i/iX Series with firmware CIC463-
5.
ABD
1
Option ABD
Airbus ABD0100.1.8 test option. Requires use of
Sequoia Virtual Windows software.
LF
2
Option LF
Limits interharmonics generator direct control output
to 500 Hz maximum.
MB
3
Option MB
Allows System field setting in Configuration menu to
be changed to support different configurations.
OPT2
Option B787
Boeing B787-0147 test option. Requires use of
Sequoia Virtual Windows software.
OPT1
Option AMD
Airbus AMD24C test option. Requires use of Sequoia
Virtual Windows software.
1
Note: *OPT? response list will not have “ABD” field if firmware revision is less than 1.13
2
Note: *OPT? response list will not have “LF” field if firmware revision is less than 1.14.

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals