Command Syntax [SOURce:]POWer[:REAL]
Parameters < NRf >
Example POW 20
Query Syntax [SOURce:]POWer[:REAL]?
Returned Parameters < NRf >
Related Commands POW:REAL?MIN, POW:REAL?MAX
[SOURce:]POWer:REACtive
Sets the Reactive power required as a load for the UUT
Command Syntax [SOURce:]POWer:REACtive
Parameters < NRf >
Example POW:REAC 10
Query Syntax [SOURce:]POWer:REACtive
Returned Parameters < NRf >
Related Commands POW:REAC?MIN, POW:REAC?MAX
4.13 Source Subsystem -Impedance (eLoad RLC Programming)
The IMPEDANCE command Programs the Resistance, Inductance and Capacitance required as a
load for the UUT
Subsystem Syntax
[SOURce:]
IMPedance < NRf > < NRf > < NRf > Sets the Resistance, Inductance and
Capacitance value
[SOURce:]IMPedance
The impedance command Programs the Resistance, Inductance and Capacitance required as a load
for the UUT.
Command Syntax [SOURce:] IMPedance
Parameters -1 to remove the connection, <NRf>
Example SOUR:IMP -1 10 13
Since -1 is programmed to Resistance, It is considered as Resistance
is not connected.
Query Syntax [SOURce:] IMPedance?
Returned Parameters < NRf >
Related Commands SOUR:IMP?MIN, SOUR:IMP?MAX

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals