EasyManuals Logo

Ametek SEQUOIA Series Programming Manual

Ametek SEQUOIA Series
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Sequoia Series 49
INSTrument:SELect
This command may be used select a specific output phase in three-phase mode using a character
reference. ā€œAā€ denotes phase A, ā€œBā€ denotes phase B and ā€œCā€ denotes Phase C. As long as the
instrument state is coupled however, programming command will affect all phases. As soon as the
INST:COUP NONE command is issued, the last selected phase becomes selected. To immediately
change the output of a single phase only, make sure the instrument state is uncoupled when issuing
the INST:SEL command.
Note that the MEASure and FETCh subsystems are not affected by the INST:COUP command and
always operate on the selected phase only. This means the instrument can remain in coupled mode
while doing measurement queries using ā€œINST:SEL <n>;FETC:VOLT?;*WAIā€. Note that when the
instrument is subsequently put in the uncoupled state using ā€œINST:COUP NONEā€, the last issued
phase selection will be in effect. To make sure the desired phase is selected, follow the ā€œINST:COUP
NONEā€ command with an ā€œINST:SEL <n>ā€ command
Command Syntax INSTrument:SEL
Parameters A | B | C
Examples INST:SEL A
Query Syntax INST:SEL?
Returned Parameters <CRD>
Related Commands INST:COUP INST:NSEL

Table of Contents

Other manuals for Ametek SEQUOIA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek SEQUOIA Series and is the answer not in the manual?

Ametek SEQUOIA Series Specifications

General IconGeneral
BrandAmetek
ModelSEQUOIA Series
CategoryPortable Generator
LanguageEnglish

Related product manuals