80 Sequoia Series
FREQuency:SLEW:TRIGgered
This command sets the rate at which frequency changes during a triggered output transient.
Instantaneous frequency changes can be obtained by sending MAXimum.
Command Syntax [SOURce:]FREQuency:SLEW:TRIGgered <NRf+>
Parameters 0.01 to 1E9MAXimum
Unit Hz (Hertz per second)
*RST Value MAXimum
Examples FREQ:SLEW:TRIG 75 FREQ:SLEW:TRIG MAX
Query Syntax [SOURce:]FREQuency:SLEW:TRIG?
Returned Parameters <NRf>
Related Commands FREQ:SLEW:MODE FREQ
FREQuency:TRIGgered
This command programs the frequency that the output will be set to during a triggered step or pulse
transient.
Command Syntax [SOURce:]FREQuency:TRIGgered <NRf+>
Parameters 0 to maximum frequency range specified by the LIMit:FREQuency
command
Unit Hz (Hertz)
*RST Value 60 Hz
Example FREQ:TRIG 50
Query Syntax [SOURce:]FREQuency:TRIGgered?
Returned Parameters <NR2>
Related Commands FREQ FREQ:MODE
FREQuency:HIGH
This command sets the soft limits for maximum output frequency to which the unit could be
programmed
Command Syntax SOURCE: FREQuency: HIGH
Parameters <NR2>
Unit Hz (Hertz)
Examples FREQ:HIGH 50
Query Syntax FREQ:HIGH?
Returned Parameters <NR2>
Related Commands FREQ FREQ:MODE
FREQuency:LOW
This command sets the soft limits for minimum output frequency to which the unit could be
programmed
Command Syntax SOURCE: FREQuency: LOW
Parameters <NR2>
Unit Hz (Hertz)
Examples FREQ: LOW 5
Query Syntax FREQ: LOW?
Returned Parameters <NR2>
Related Commands FREQ FREQ:MODE