Sequoia Series 91
SENSe:SWEep:TINTerval
This command and its query format allow setting the time period between samples when voltage and
current digitization is controlled by the acquire trigger sequence. The query response of the
sample period query will be:
10.4 to 104 sec for single phase and 31.2 to 312 sec for three phase power source configurations
respectively. The value of TINT must be set in increments of 10.4 or 31.2 sec. The controller will
round to the nearest available multiple of 10.4 or 31.2 sec.
Command Syntax SENSe:SWEep:TINTerval <NRf+>
Parameters 10.666 to 106.666 for single phase configuration
31.2 to 312 for three phase configuration
*RST Value 10.4 or 31.2
Examples SENS:SWE:TINT-150
Query Syntax SENSe:SWEep:TINTerval?
Returned Parameters <NR2>
Related Commands SENS:SWE:OFFS MEAS:ARR

Table of Contents