If an alarm is triggered, on temperature and time display is shown the
name of the alarm triggered.
Name Description Actions
Chamber
probe
Chamber probe
failure
Cooking
cycle block;
automatic
reset.
Replace the chamber probe.
Pin
probe
Pin probe failure Manual reset. Replace the pin probe.
Safety
motor
Motor Alarm Cooking
cycle block;
automatic
reset.
If the problem persists, contact
the support center.
Peripheral Motor Inverter
Alarm
Cooking
cycle block;
automatic
reset.
Cut off the power and power
again.
If the problem persists, contact
the support center.
Chamber
safety switch
Chamber thermal
breaker
Cooking
cycle block;
automatic
reset.
If the problem persists, contact
the support center.
Hi temp
the technical
compartment is too
high
Cooking
cycle block;
automatic
reset.
Check the perimeter of the oven
(slits) and the correct operation
of parts cooling fans.
No
water
generate steam
Cooking
cycle block;
automatic
reset.
Check the connection to water
pipeline and make sure the shut-
off valve is open.
Communica-
tion
Main board
communication
failure
Cooking cycle
block.
Cut off the power and power
again. If the problem persists,
contact the support center.
Power fail Electric power
supply is
interrupted
Cooking cycle
block.
Press M for 1 second.
Probe 4 Moisture control
probe 4 alarm
Cooking cycle
block.
Replace the moisture control probe
4
Probe 5 Moisture control
probe 5 alarm
Cooking cycle
block.
Replace the moisture control probe
5