EasyManua.ls Logo

Anybus CompactCom 40 - Page 105

Anybus CompactCom 40
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Anybus Module Objects 103 (258)
Instance Attributes (Instance #12, Domain name)
This instance holds the domain name. Changes are valid after reset.
# Name Access Data Type Description
1 Name Get Array of
CHAR
“Host name”
(Multilingual, see page 106)
2 Data type Get UINT8 07h (= CHAR)
3 Number of elements Get UINT8 30h (48 elements)
4 Descriptor Get UINT8 07h (read/write/shared access)
5 Value Get/Set Array of
CHAR
If read, the actual value will be received. If written, the written
value is reflected in attribute #6 until a reset.
Domain name, 48 characters
6 Configured Value Get Array of
CHAR
Holds the configured value, which will be written to attribute #5
after the module has been reset.
Domain name, 48 characters
Instance Attributes (Instance #13, SMTP Server)
This instance holds the SMTP server address. Changes are valid after reset.
# Name Access Data Type Description
1 Name Get Array of
CHAR
“SMTP server”
(Multilingual, see page 106)
2 Data type Get UINT8 07h (= CHAR)
3 Number of elements Get UINT8 40h (64 elements)
4 Descriptor Get UINT8 07h (read/write/shared access)
5 Value Get/Set Array of
CHAR
If read, the actual value will be received. If written, the written
value is reflected in attribute #6 until a reset.
SMTP server address, 64 characters.
6 Configured Value Get Array of
CHAR
Holds the configured value, which will be written to attribute #5
after the module has been reset.
SMTP server address, 64 characters.
Instance Attributes (Instance #14, SMTP User)
This instance holds the user name for the SMTP account. Changes are valid after reset.
# Name Access Data Type Description
1 Name Get Array of
CHAR
“SMTP user”
(Multilingual, see page 106)
2 Data type Get UINT8 07h (= CHAR)
3 Number of elements Get UINT8 40h (64 elements)
4 Descriptor Get UINT8 07h (read/write/shared access)
5 Value Get/Set Array of
CHAR
If read, the actual value will be received. If written, the written
value is reflected in attribute #6 until a reset.
SMTP account user name, 64 characters
6 Configured Value Get Array of
CHAR
Holds the configured value, which will be written to attribute #5
after the module has been reset.
SMTP account user name, 64 characters
Anybus
®
CompactCom
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8

Table of Contents

Related product manuals