USE AND MAINTENANCE MANUAL
ATTILA
31
EN
POS. ICON DESCRIPTION
10
Steady on
Active maintenance cycle
Flashing
current displayed time represents the current duration of the maintenance cycle
11
Indicates that an alarm is active (both blocking and non-blocking)
7.3.2. DISPLAY - MESSAGES
MESSAGE DESCRIPTION
STAND-BY Displays 'Stby', after first switch-on, with device in stand-by mode.
DEFROSTING Displays 'Sbri' by pressing the Stop button.
MANUAL CYCLE IN
PROGRESS
Displays the time remaining until the end of the cycle
(example: 3 minutes are indicated as '0:03')
AUTOMATIC CYCLE IN
PROGRESS
Displays the temperature detected by the core probe
ONGOING PRESERVATION
CYCLE
Displays the duration of the blasting cycle (during storage), alternately followed by the
duration of the maintenance cycle if the last programme was run in manual mode, otherwise
it displays the temperature measured by the pin.
ALTERNATIVE DISPLAYS
Displays the chamber probe temperature for 5 seconds by pressing the Up button.
After the timeout, the display for the current cycle returns.
Displays the elapsed time from the start of the cycle while holding down the Set button.
If the preservation cycle is active, it displays the duration of the cycle that has just ended
(before preservation). When the Set button is released, the display for the current cycle
returns.
SET UP DOOR OPEN
Displays 'PAP'(open door)
Note: the message only appears during the execution of a programme, or if the door is
opened while the programme is running.
Programme execution is not suspended and in manual mode, the time count continues even
when the door is open; instead, consent on loads is suspended
When the door is closed, load activation resumes. If during programme execution, with the
door open, the Start button is pressed, the programme stops, the message 'PAP' disappears
and the programme returns to the STOP status.