USE AND MAINTENANCE MANUAL
ATTILA
73
EN
13.2.4. 'ALADINO' VERSION BLAST CHILLER PARAMETERS
SIC - Safety
PARAMETER DESCRIPTION UM R290
R455a/
R452a
Min Max
PAS Entering passwords to access protected menus 111 111 0 999
dro Display in °C (0) or °F (1) 0 0 0 1
H01 Display Language ( 0 - Ita, 1 - Eng, 2 - Fra ) 0 0 0 15
LP3 Programme 3 - Pin setpoint [°C] °C -35 -35 -45 25
13.2.5. 'ALADINO' VERSION ADVANCED BLAST CHILLER PARAMETERS
Access to advanced parameters is password-protected and restricted to qualied personnel
only
CHIL - Parameters
PARAMETER DESCRIPTION UM R290
R455a/
R452a
Min Max
CA1 Calibration Probe 1 [0.1°C] 0.1°C 0 0 -25 25
CA2 Calibration Probe 2 [0.1°C] 0.1°C 0 0 -25 25
CA3 Calibration Probe 3 [0.1°C] 0.1°C 0 0 -25 25
CA4 Calibration Probe 4 [0.1°C] 0.1°C 0 0 -25 25
diF
Compressor adjustment hysteresis (always positive)
[0.1°C]
0.1°C 30 30 10 50
CSd
Compressor protection before a start-up
(compressor call waiting time) [Minutes]
min 2 2 1 30
Crd
Minimum delay between two successive ignitions
[Minutes]
min 3 3 1 30
PCt
Minimum difference between chamber and pin check
pin inserted [0.1°C]
0.1°C 50 50 -150 150
PCd
Time to recheck chamber and pin difference to
switch to timed cooking
min 4 4 0 240
PCn
Number of rechecks to verify correct insertion of
core probe
2 2 0 10
LP1 Programme 1 - Pin setpoint [°C] °C 3 3 -45 25
Ot1 Programme 1 - Chamber setpoint (delta on pin) [°C] °C -5 -5 -45 25
Ft1
Programme 1 - Chamber setpoint maintenance
(delta on pin) [°C]
°C -3 -3 -45 25