8.5. USE OF “TOUCH” VERSION BLAST CHILLER
8.5.1. ACTIVATION
Do not start the equipment with wet hands or when there is contact with water.
STEP ACTION PICTURE
1
Press the O/I main switch.
Note: when switched on, the button lights up green.
2
Press and hold the button for 4 seconds to switch on the equipment.
8.5.2. BLASTING MODES
The blasting cycle can be configured using the buttons:
• TARGET - Timed or with core probe
• TEMPERATURE - positive (+3°C) or negative (-18°C)
• MODE - Soft or Hard.
The combination of the above selections produces eight blasting cycles:
TARGET TEMPERATURE METHOD
PARAMETER
VALUE
DISPLAY STRING
Timed
Positive
Hard 0 PMH
Soft 1 PMS
Negative
Hard 4 PAH
Soft 5 PAS
With core probe
Positive
Hard 2 nMH
Soft 3 nMS
Negative
Hard 6 nAS
Soft 7 hLd