11.1.3. 'ALADINO' VERSION BLAST CHILLER ALARMS
MESSAGE CAUSE TYPE OF ERROR SOLUTIONS
Pr 1
Check that all terminal board wires
are plugged in.
Chamber probe error.
If the wire is disconnected,
reinsert it into the terminal
and tighten the screw.
Pr 2
Check that all terminal board wires
are plugged in.
Core probe error.
If the wire is disconnected,
reinsert it into the terminal
and tighten the screw.
Pr 3
Check that all terminal board wires
are plugged in.
Condenser probe error.
If the wire is disconnected,
reinsert it into the terminal
and tighten the screw.
P AP
Door open. Door open.
Check that the door is
closed properly.
Cprs
Blasting times too long.
Chamber setpoint not
reached in the preset
maximum time.
Change the set times.
TOut
Incorrectly positioned pin.
Product weight above limits.
Core temperature not
reached in the preset
maximum time.
Check pin position.
Change the set times.
Reduce the amount of
product according to the
machine's capacity.