ATTILA
EN
74
PARAMETER DESCRIPTION UM R290
R455a/
R452a
Min Max
St1
Programme 1 - Maximum compressor on time
before reaching setpoint [Minutes]
min 0 0 1 9999
OH1
Programme 1 - Timed blast chilling duration in
hours
h 1 1 0 250
On1
Programme 1 - Timed blast chilling duration in
minutes
min 30 30 0 59
tH1 Programme 1 - Core blasting timeout hours h 3 3 0 250
tn1 Programme 1 - Core blasting timeout minutes min 0 0 0 59
PE1
Programme 1 - Blast chilling type selection (0 -
timed, 1 - core probe)
1 1 0 1
LP2 Programme 2 - Pin setpoint [°C] °C -18 -18 -45 25
Ot2 Programme 2 - Chamber setpoint (delta on pin) [°C] °C -17 -17 -45 25
Ft2
Programme 2 - Chamber setpoint maintenance
(delta on pin) [°C]
°C -7 -7 -45 25
St2
Programme 2 - Maximum compressor on time
before reaching setpoint [Minutes]
min 0 0 1 9999
OH2
Programme 2 - Timed blast chilling duration in
hours
h 4 4 0 250
On2
Programme 2 - Timed blast chilling duration in
minutes
min 30 30 0 59
tH2 Programme 2 - Core blasting timeout hours h 9 9 0 250
tn2 Programme 2 - Core blasting timeout minutes min 0 0 0 59
PE2
Programme 2 - Blast chilling type selection (0 -
timed, 1 - core probe)
1 1 0 1
LP3 Programme 3 - Pin setpoint [°C] °C -35 -35 -45 25
Ot3 Programme 3 - Chamber setpoint (delta on pin) [°C] °C -8 -5 -45 25
Ft3
Programme 3 - Chamber setpoint maintenance
(delta on pin) [°C]
°C -3 -3 -45 25
St3
Programme 3 - Maximum compressor on time
before reaching setpoint [Minutes]
min 0 0 1 9999
OH3
Programme 3 - Timed blast chilling duration in
hours
h 4 4 0 250
On3
Programme 3 - Timed blast chilling duration in
minutes
min 30 30 0 59
tH3 Programme 3 - Core blasting timeout hours h 9 9 0 250
tn3 Programme 3 - Core blasting timeout minutes min 0 0 0 59
PE3
Programme 3 - Blast chilling type selection (0 -
timed, 1 - core probe)
1 1 0 1