PARAMETER DESCRIPTION Min Max Def.4R Def.3R UM
17 Chamber Set for positive storage. -50 99 0 0 °C
18 Chamber Set for negative storage. -50 99 -25 -25 °C
19 Positive timed blasting duration. 0 599 89 89 Min
20 Negative timed blasting duration. 0 599 270 270 Min
21 Condenser temperature set, for secondary fan. -50 99 34 34 °C
22 Enabling 2nd condenser fan. 1 0 1 1 no.
23
Configuration relay 4
0 = disabled
1 = UV lamp
2=core probe heating
3= 3rd condenser fan.
0 3 3 0 no.
24 Setting sterilisation duration. 1 999 15 15 Min
25 Setting sterilisation temperature threshold. -50 99 5 5 °C
26 Temperature threshold setting 3rd condenser fan. -50 99 36 36 °C
27
Pressure switch setting
0=pressure switch disabled
1,2,3,4 = alarm events counting before locking loads.
0 4 0 0 no.
28 Setting core probe heating duration. 1 10 2 2 Min
29 Core probe heating temperature setpoint. 0 90 4 4 °C