17
4.1.2.1 Bluetooth Connection
Bluetooth pairing is recommended as the first choice for the communication between the
MaxiTPMS tablet and the MaxiVCI V200. This is because the Bluetooth connection does
not need to repeat the plugging and unplugging procedure which is unavoidable when
using traditional wired connection, saving more time and providing higher efficiency. The
working range for Bluetooth communication is about 33 feet (about 10 m), enabling
remote vehicle diagnostics.
Refer to Bluetooth Connection for detailed information.
4.1.2.2 USB-C to USB-C Cable Connection
The communication between the MaxiTPMS tablet and the MaxiVCI V200 device can
also be established using a USB-C to USB-C cable. However, the USB-C to USB-C cable
is not included in the package. If you choose this method to establish a communication
between the devices, a USB-C to USB-C cable should be prepared by yourself.
4.1.3 No Communication Message
1. If the MaxiTPMS tablet is not connected to the MaxiVCI V200 correctly, an “Error”
message may display. This indicates that the tablet cannot access the vehicle control
module. In this case, please do the following check-ups:
Check if the MaxiVCI V200 is powered up.
Check if the MaxiVCI V200 is properly positioned.
Check if the Vehicle/Connection LED on the MaxiVCI V200 is illuminated for
Bluetooth or USB-C to USB-C cable connection.
In the case of Bluetooth connection, check if the network is configured correctly,
or if the right MaxiVCI V200 has been paired up with the MaxiTPMS tablet.
During the diagnosis process, if the communication is suddenly interrupted
due to the loss of signal, check if there is any object that causes signal
interruption.
Try standing closer to the MaxiVCI V200 to obtain more stable signals and
faster communication speed.
In the case of USB-C to USB-C cable connection, check the cable connection
between the MaxiTPMS tablet and the MaxiVCI V200.
2. If the MaxiVCI V200 is unable to establish a communication link, a prompt message
displays with check instructions. The following conditions are the possible causes:
The MaxiVCI V200 is unable to establish a communication link with the vehicle.
The system selected for testing is not equipped on the vehicle.