4. Troubleshooting
1
2
Image 4-38
Light processor cover tamper switches
Code 5807: ti-icp - read system status failed” (Error)
The Barco controller can not read the status of the ICP.
Situation Solution
ICP board is not correctly inserted Insert t he ICP board properly.
ICP crash. The m ost left LED is not
blinking
Restart the projector.
ICP is being upgrading Wait until projector reset after the upgr ade.
Code 5812: “ti-icp - read satellite info failed” (Error)
Situation Solution
A wire unit to one of the formatters
is not correctly connected to the
Signal backplane (reference 1, 2, 3
for green on image 4-39).
Check the connections between the formatters and the Signal backplane on the Signal
backplane side.
A wire unit on one of the formatters
is not c orrectly connected (reference
4, 5 , 6 for red on image 4-39)
Check the connections between the form atters and the Signal b ackplane on the
formatter s ide.
1
2
3
5
4
6
Image 4-39
Formatter connections
Code 5813: “ti-icp - satellite rmware mismatch” (Error)
This error can occur w hen you move ICP boards between projectors wh ich have a different DMD c ongura tion. (E.g. switching an
ICP b etween a 1.2 and 0.98 inc h system)