14.2. INSPECTIONS
The storage bottles have to be maintained at regular inter
vals. This results in inner inspections every 5 years, pressure
tests every 10 years and outer inspections every 2 years,
which have to be performed by the local authorities.
14.3. CONDENSATE DRAIN
Drain condensate at a regular basis. The amount of con
densate depends on the condition of compressed medium,
on the flow rate as well as on the ambient temperature, and
should be determined individually for every single applica
tion.
15. REPAIR INSTRUCTIONS
Preventive maintenance usually involves replacing the
valves, gaskets and sealing rings as well as carrying out the
maintenance work according to the maintenance schedule
in chapter D.1.
All further maintenance and repair work
not contained in this manual have to be
performed by an authorized technical
service. It is particularly pointed out that
- no repair should be carried out on the
crankdrive or on the bearings
- safety valves are not repaired but always
replaced completely.