Fig. 55 Operation menu
Fig. 56 Operation modes
Instruction Manual w VERTICUS 5 Compressor Units
A-55
11.4.10. Parameterization
The parametrization of a combined
compressors installation should be carried
out by an experienced operator or a BAUER
service technician only.
Operation
The Operation menu (Fig. 55) contains several sub-menus
for the setting of the following parameters:
Operation modes
Control settings
Combination parameters
Pressure value setting (depending on unit configuration)
Operation mode
The Operation mode list field allows to select a specific ope
ration mode:
Semi-automatic,
Fully automatic or
Combined operation.
Refer to chap. 11.3.1. for a description of the operating
modes.
When „Combined operation“ is selected, all
active slaves of the installation must be also
set to "Combined operation". Refer to the
manual of the corresponding compressor to adjust the
operation mode.
Safety valve test mode
The compressor is started manually and will not be
switched off until the “0” key is pressed. The final pressure
sensors are disabled and the compressor will operate
against the safety valves. By this a safety valve blow off test
can be performed in a simple way.
Use this operation mode under survey,
only.
Leak test mode
In the leak test mode, the compressor is started manually
and will switch off automatically after having reached the
final pressure. During this mode, venting of the condensate
drain valves is disabled. The compressor remains under
pressure. By this an air tightness or leak test can be
performed in a simple way.