No: RemedyCauseFault message
67 Fan 2 Motor protection
triggered
Fan overload Check fan for free movement.
Check wiring.
Reset circuit breaker
Wrong setting Adjust circuit breaker according to
schematic diagram.
Circuit breaker defective Check circuit breaker, replace if
necessary
68 SECURUS gestört SECURUS-Sensor or wiring defective Check SECURUS sensor and wiring,
replace if necessary.
69 SECURUS Filterwechsel
Vorwarnung
Filter cartridge bald gesättigt Order filter cartridge.
70 SECURUS Filter gesättigt Filter cartridge gesättigt Replace filter cartridge
71 SECCANT gestört Repair fault
72 SECCANT CAN gestört Bus, -connection defective Check and repair bus.
73 B-KOOL or AIR-KOOL faulty Repair dryer. See operating manual.
74 Condensate tank full Too much condensate produced Empty condensate tank
75 Pressure in manifold high Check opening pressure of safety valves,
replace if necessary
76 SECURUS external monitoring
unig, filter saturated
Filter cartridge saturated Replace filter cartridge
77 Combined operation Slave 1
faulty
compressor defective Troubleshoot
78 Combined operation Slave 2
faulty
compressor defective Troubleshoot
79 Combined operation Slave 3
faulty
compressor defective Troubleshoot
80 Combined operation Slave 4
faulty
compressor defective Troubleshoot
81 spare
82 Gas warning unit faulty Gas warning unit defective Repair gas warning unit. See operating
manual.
83 Gas warning > 20% Leakage Check unit for leakage and repair
84 Gas alarm > 40% Leakage Check unit for leakage and repair
85 Emergency OFF ATEX triggered Emergency OFF gedrückt Check and reset Emergency OFF.
86 Emergency OFF triggered Emergency OFF gedrückt Check and reset Emergency OFF.
87 Spare
88 SECURUS offline ____
89 X2X-Link faulty Communication failure between B-Con
trol panel and I/O-unit
Check bus (violet).
90 B-messenger faulty
91 Compressor maintenance due Target times reached. Service compressor.
92 Backup battery empty Backup battery empty or soon empty Replace backup battery. Refer to
operation manual
93 Fault input 1 triggered
94 Fault input 2 triggered