Baumer_EAx_EtherNetIP_EN_MNL 67/81 www.baumer.com
02.20
Instance Attribute 109 - Number of Spans
This instance attribute contains the maximum number of distinguishable revolutions.
Default value
65536 = 0x10000 (for "MT16ST13" device variant)
65536 = 0x10000 (for "MT16ST14" device variant)
8192 = 0x2000 (for "MT13ST18" device variant)
The physical measurement range is calculated as follows:
Physical measurement range = attribute 42 (Physical Resolution Span) x attribute 109 (Number of Spans)
Instance Attribute 110 - Set Parameter Non-Volatile
This instance attribute defines the kind of setting parameters. Depending on the value one of the following
behaviours is active: Default Parameter Behaviour / Alternative Parameter Behaviour. The parameter is set
non-volatile.