10. Turn the calibration plate, and hold it in place when
it is centered across from the shaft until the beam
intersects with the holes.
651127-93_BM
Fig. 112: Laser beam being emitted
i Lock the spacer plate on the calibration plate again.
11. Push the pedal up.
The tie rod will move to the left.
The spacer plate will be pressed against the cali-
bration plate.
The calibration plate is now fixed in place.
! Once the beam intersects with all the holes, the
calibration will be complete. If it does not, adjust
the position of the accessories in the places
pictured and make sure the position of the laser
beam is correct.
Fig. 113: Adjusting an external laser
" Calibration complete.
12. Remove the spacer plate and the calibration plate.
13. Install the cover of the sonar probe.