Measures for suppressing interference:
With severely contaminated mains supplies (e.g. when "thyristor-controlled systems" are
used) measures must be taken on-site to suppress interferences, e.g.:
– A separate supply line must be planned for Bizerba machines.
– In problem cases, install capacitively decoupled isolating transformers or other suppres-
sors into the supply mains prior to Bizerba machines.
Availability of the power plug used as a supply circuit disconnect
Make sure that any access point allows you to check whether the plug is disconnected.
4.2.3 Leveling
In order to ensure the scale's accuracy, machine must be installed horizontally.
Leveling of GSP H Flex
Turn feet of machine until air bubble is in
the center of the spirit level .
Machine is installed horizontally.
Fig.10: Leveling
Re-level scale after each change of location.