03/12 EM-ABS-01 for ACU 107
8.4.9.1 Example 1
Additional bits (High) Multiturn
bits
Singleturn bits Additional bits (Low)
0 8 16 Total 1 to be evaluated.
“High” is an error situa-
tion.
SSI: Error-/Extra-Bits (High) 1270 = “-”
B
its Multiturn. 1272 = 8
B
its/Turn 1271 = 16
SSI: Error-/Extra-Bits (Low) 1269 = “-”
8.4.9.2 Example 2
Additional bits (High) Multiturn
bits
Singleturn bits Additional bits (Low)
0 12 16 Total 4, the second one
is to be evaluated.
“Low” is an error situa-
tion.
SSI: Error-/Extra-Bits (High) 1270 = “-”
B
its Multiturn. 1272 = 12
B
its/Turn 1271 = 16
SSI: Error-/Extra-Bits (Low) 1269= “XLXX”
8.4.9.3 Example 3
Additional bits (High) Multiturn
bits
Singleturn bits Additional bits (Low)
Total 2, the first one is to
be evaluated. “High” is an
error situation.
8 16 Total 4, the second one
is to be evaluated.
“Low” is an error situa-
tion.
SSI: Error-/Extra-Bits (High) 1270 = “HX”
B
its Multiturn. 1272 = 8
B
its/Turn 1271 = 16
SSI: Error-/Extra-Bits (Low) 1269= “XLXX”
8.4.9.4 Example 4
Additional bits (High) Multiturn
bits
Singleturn bits Additional bits (Low)
0 8 16 Encoder has 4 toggle
bits all of which are to
be ignored.
SSI: Error-/Extra-Bits (High) 1270 = “-”
B
its Multiturn. 1272 = 8
B
its/Turn 1271 = 16
SSI: Error-/Extra-Bits (Low) 1269= “XXXX”