DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 102
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Format for Destination 1 (2)
• Address:
- Format for Destination 1: 0064
- Format for Destination 2: 0130
• Default: 2 (Contact ID)
• Selections:
- 2 = Contact ID
- 3 = SIA 300
- 4 = Basic Pager
- 6 = BSIA Fast Format
- 7 = Personal Dialing Format
- 11 = SIA 300 with Text Blocks
If network communication is enabled, the control panel automatically selects Contact ID as the
reporting format. Contact ID only supports four-digit account numbers. This results in the control
panel automatically truncating account numbers to four digits.
Alternate Communication Options
• Address:
- IP Address 1, Destination 1: 3506
- IP Address 2, Destination 1: 3514
- IP Address 1, Destination 2: 3522
- IP Address 2, Destination 2: 3530
• Default: 0
• Selections: 0, 1, 3, 5, 7
Enter This Data Digit to Select Options
Alternate Communication Options
No Alternate Communication
Enable Alternate Communication
• Enable Alternate Communication: Select this option to enable network communication. You must
enter at least one IP address as a routing destination. See IP Address 1 (2) for Destination 1 (2) on
page 101 for more information.
• Enable Anti-Replay: Anti-replay prevents unauthorized messages from being sent to the Alarm
Receiving Center (ARC) and being recognized as having originated from the control panel. Select
this option to use the anti-replay procedure. To use this option, make sure “Include IP Address” is
enabled.
• Use ARC Acks: If this option is enabled, the control panel waits for an acknowledgment (Ack)
from the ARC before sending a second message. If this option is disabled, the control panel waits
approximately 120 sec. between sending messages (disable only for special applications).