Table 40: Control Panel Events and Reporting Formats (continued)
Event as shown
in Control Panel
Log
Zone Types
Linked to
Event
130 Dbus Troubl,Rstl ER Expansion
Restoral
330 System
Peripheral
Trouble
Data Bus Device Fault
(Trouble) condition cleared.
12 R S
131 Dbus OverCurrent YI Overcurrent
Trouble
330 System
Peripheral
Trouble
Over current condition
detected on Data Bus device.
12 R S
132 Dbus OvrCur,Rstl YJ Overcurrent
Restore
330 System
Peripheral
Trouble
Over current condition on Data
Bus device restored.
12 R S
133 Sensor Mon Trbl NA No Activity 391 Sensor
Watch
trouble
Sensor fault (trouble)
detected. Reports follow zone
trouble routing.
11-15 Zone
Types
6
134 Sensor Mon Rstl NS Activity
Restored
391 Sensor
Watch
trouble
Sensor trouble condition
restored. Reports follow zone
trouble routing.
11-15 Zone
Types
6
135 Sensor Reset Local Event
Only
User entered System Reset key
sequence ([#][4][7]).
12
136 System Inactive CD Closing
Delinquent
System was not armed in
Inactive Interval.. System Reset
key sequence ([#][4][7]) or
arming resets this trouble.
12 R
Test
Test Report
automatic test report time.
138 Test,Off-Normal RY Test Off
Normal
608 Period
Test Report,
System
Trouble
Present
System trouble present at test
time.
13
139 Trbl,Tamper TT Tamper
Trouble
380 Sensor
Trouble
Trouble condition on Tamper
or any tamper-wired zones.
4-Tamper
or any zone
6
140 Trbl,Emergency QT Emergency
Trouble
380 Sensor
Trouble
Trouble condition on
Emergency zone type.
5- Emergency 6
141 Trbl,Panic PT Panic
Trouble
375 Panic
Zone Trouble
Trouble condition on Panic
zone type.
6- Visible
Panic
6
142 Trbl,Invisible HT Holdup
Trouble
375 Panic
Zone Trouble
Trouble condition on Invisible
zone type.
7-Invisible
Panic
6
143 Trbl,24-hr Burg BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on Burglary
zone type.
6- Burglary
15 – Door
6
144 Trbl,Cntrl,Dly BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on Delay
zone types.
11- E/E Delay
1
12- E/E Delay
2
6
145 Trbl,Cntrl BT Burglary
Trouble
380 Sensor
Trouble
Trouble condition on
Keyswitch, Follower, and
Instant zone types.
6- Keyswitch
13- Follower
14- Instant
6
146 Rstrl,Trbl,Tmpr TJ Tamper
Trouble Restore
380 Sensor
Trouble
Restoral from Tamper trouble
condition.
4-Tamper
or any zone
8
147 Rstrl,Trbl,Emerg QJ Emergency
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition
on Emergency zone type.
5- Emergency 8
148 Rstrl,Trbl,Panic PJ Panic
Trouble Restore
375 Panic
Zone Trouble
Restoral from trouble condition
on Panic zone type.
6- Visible