Table 40: Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
SIA Report
Contact ID
Report
Event Description
Zone Types
Linked to
Event
RPS
Event
Group
Status
Report
149 Rstrl,Trbl,Invis HJ Holdup
Trouble Restore
375 Panic
Zone Trouble
Restoral from trouble condition
on Invisible zone type.
7- Invisible
Panic
8
150 Rstrl,Trbl,24-hr BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition
on Burglary zone type.
8- Burglary
15 - Door
8
151 Rstrl,Trbl,Dly BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition
on Delay zone types.
11- E/E Delay 1
12- E/E Delay 2
8
152 Rstrl,Trbl,Cntrl BJ Burglary
Trouble Restore
380 Sensor
Trouble
Restoral from trouble condition
on Keyswitch, Follower, and
Instant zone types.
10- Keyswitch
13- Follower
14- Instant
8
153 User Code Area
Set
JY User Code
Added
User Code ‘added’ by assigning
area.
16 R
154 User Code Change JV User Code
Changed
User Code changed. 16 R
155 User Code Delete JX User Code
Deleted
User Code deleted. 16 R
156 User Code Tamper JA User Code
Tamper
461 Wrong
Code Entry
Invalid User Codes entered at
keypad exceeded User Tamper
Retry Count. See page 69.
16 R
157 User Level Set JZ User Level
Set
User Level set. 16 R
158 Walk Test Start TS Test Start 607 Walk Test
Mode
Walk Test started with Walk Test
key sequence ([#][4][4]).
11
159 Walk Test End TE Test End 607 Walk Test
Mode
Walk Test ended by user or
timed out.
11
160 Siren Trouble YA Bell Fault 320 Sounder
Relay
Trouble condition detected on
PO 2 configured as supervised
siren output.
12 R S
161 Siren Restoral YH Bell Restored 320 Sounder
Relay
Trouble condition on supervised
siren output cleared.
12 R S
162 Grnd Fault IA Equipment
Failure
Condition
310 Ground
Fault
Ground fault detected on panel’s
sensor loops, Option Bus, or Aux
power outputs.
12 R S
163 Grnd Fault, Rstl IR Equipment
Fail Restoral
310 Ground
Fault
Ground fault condition cleared. 12 R S
164 First Open OP Opening
Report
400
Open/Close
Panel is configured for multiple
area first to open, last to close
function. See Arming Options 2
on page 63. First area has
opened.
10
165 Last Close CL Closing
Report
400
Open/Close
Panel is configured for multiple
area first to open, last to close
function. See Arming Options 2
on page 63. Last area has closed.
10
166 AltCom Cond NC Network
Condition
350
Communicatio
n Trouble
Trouble detected on Alternate
Communication network.
12 R S
167 AltComm Fail NT Network
Failure
350
Communicatio
n Trouble
Network failure detected on
Alternate Communication
network.
12 R S
168 AltComm Rstrl NR Network
Restoral
350
Communicatio
n Trouble
Network communication
resumed on alternate
communications network.
12 R S