DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 118
Table 40: Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
SIA Report
Contact ID
Report
Event Description
Zone Types
Linked to
Event
RPS
Event
Group
Status
Report
169 Reserved
170 Reserved
171 Reserved
172 Reserved
173 Rstrl, Swinger BU Burglary
Unbypass
575 Swinger
Shunt
Restoral from Swinger Shunt. Any zone type 8
174 Rstrl,Fire,Miss Local Event
Only
Local Event
Only
Restoral from Fire Missing.
Local event, no report.
1- Fire
2- Fire with
Alarm
Verification
7
175 Rstrl,Alarm,Miss Local Event
Only
Local Event
Only
Restoral from Missing, Non-Fire
zones. Local event, no report
sent.
Any non-fire
zone type
8
176 Rstrl,Trble,Miss Local Event
Only
Local Event
Only
Restoral from Fault (Trouble),
Non-Fire zones. Local event, no
report.
Any non-fire
zone type
8
177 Rstl,Low Signl Local Event
Only
Local Event
Only
Restoral from Alternate
Communication Low Signal
Strength event.
12 R S
178 UnBypss,Fire,RPS FU Fire
Unbypass
571 Fire
bypass
Bypass on Fire zone type
cleared using RPS (un-bypass).
1- Fire
2- Fire with
Alarm
Verification
179 UnBypss,Ctrl,RPS BU Burglary
Unbypass
570
Zone/Sensor
bypass
Bypass on zone type cleared
using RPS (un-bypass).
10 to 15- Zone
Types
180 UnBypss,24hr,
RPS
BU Burglary
Unbypass
572 24 hour
zone bypass
Bypass on 24-hour zone type
cleared using RPS (un-bypass).
3 to 9- 24-
hour, Non-Fire
Zone Types
181* RF Battery Low XT Transmitter
Battery Trouble
384 RF Low
Battery
Low battery condition on RF
Keyfob.
9 R
182* RF Battery Rstl XR Transmitter
Battery
Restoral
384 RF Low
Battery
Low battery condition on RF
Keyfob restored.
9 R
183 Trbl,Default PIN Local Event
Only
Local Event
Only
Installer or User PINS have not
been changed from default.
184 Rstl,Default PIN Local Event
Only
Local Event
Only
Installer or User default PINS
have been changed.
185 Failed to Arm EE Exit Error 454 Failed to
Close
Arming attempt failed. 3
186 Verified Alarm BV Burglary
Verified Alarm
139 Intrusion Verified Alarm. 3
187 Dbus Missng Alrm TA Tamper
Alarm
137 Tamper
Alarm
Data bus device not
responding to polling. (Shows
Zone 41).
12 R S
188 Dbs Mis Alm Rstl TR Tamper
Restoral
137 Tamper
Alarm
Data bus device declared as
missing now responding to
polling. (Shows Zone 41).
12 R S
189 Dbus Tamper
Alrm
TA Tamper
Alarm
137 Tamper
Alarm
Tamper open on Data bus
Device Tamper. (Shows Zone
42).
12 R S
* This event reports a user number + 200 when sent using SIA and Contact reporting formats.