DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 64
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Open/Close Reporting Options
• Address: 0261
• Default: 3
• Selections: 0 to 15
Enter This Data Digit to Select Options
Open/Close Reporting Options
No Open, Close, Exit Error, or Recent Close
Reports
Opening {89-96, 164} Reports Enabled
Closing {42-67, 165} Reports Enabled
Exit Error {18} Report Enabled
Recent Closing {19-20} Reports Enabled
This is a global parameter that affects all zones, all areas, and all PINs.
Opening and Closing reports can be restricted by area (see Area # Opening {89-96}/Closing
{42-67} Reporting Options on page 66) and by Authority Level once they are enabled and
configured here. Reporting must be enabled at the system level first (see Global Reporting
Options on page 58).
• Opening Reports Enabled: If selected, this option enables Opening {89 to 96, 164} reports.
• Closing Reports Enabled: If selected, this option enables Closing {42 to 67, 165} reports.
• Exit Error: Only the Exit Error {18} report is enabled and disabled by this option. If an Entry/Exit
Delay zone (Zone Function Types 11 and 12) is violated at the end of Exit Delay, these events
occur in this order:
1. Local alarm annunciation starts (keypads and alarm outputs)
2. Entry Delay starts
3. The alarm report process begins if the system is not turned off at the end of Entry Delay. An
Exit Error {18} report is included if programmed. The Exit Error report follows the Alarm
Report routing.
• Recent Closing: If this option is enabled, an Alarm Recent Closing {19 to 20} report (including the
user number) is sent for any alarm within 2 min. of the end of Exit Time.