DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 63
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Arming Options 2
• Address: 0259
• Default: 12
• Selections: 0 to 15
Enter This Data Digit to Select Options
First Area to Open/Last Area to Close
Reporting
Enable All Areas All On ([#][8][0])
Enable All Areas All Off ([#][8][1])
• First Area to Open {164}/Last Area to Close {165} Reporting: If this option is enabled, the
system sends one Closing {165} report when all areas are turned On and one Opening {164}
report when any area is turned Off. Opening/Closing reports must be enabled for all areas.
Enabling the “Restrict Open/Close Reports” option overrides the “First Area to Open/Last
Area to Close Reporting” option. See Area # Opening {89-96}/Closing {42-67} Reporting
Options on page 66 for more information on the “Restrict Open/Close Reports” option.
All area account numbers must be the same in order to send Area 1’s account numbers.
See Area-Wide Parameters on page 65 for account number programming instructions.
• Make Area 1 Common Area: If this option is enabled, all other areas are made common to Area 1.
Area 1 arms when all the other areas are armed All On, and Area 1 disarms when any other area is
disarmed.
• Enable All Areas All On ([#][8][0]): If this option is enabled, all areas arm when a user enters
[#][8][0]. Faulted zones are force-armed. Enable all areas in which the user has the appropriate
authority level.
• Enable All Areas Off ([#][8][1]): If this option is enabled, all areas disarm when a user enters
[#][8][1]. This function always requires a PIN. Enable all areas in which the user has the
appropriate authority level.