1 689 975 233 2018-05-08| Robert Bosch GmbH
Repair | EPS 708 | 51 en
6.21.3 Resetting the frequency converter
458863-36_Ri
1
2
Fig. 85: Frequency converter
1. Remove the front cover of the electrical
compartment.
2. Switch on the EPS 708 at the master switch.
The frequency converter (item 1) detects a new
drive motor.
3. Press <ENTER> (item 2) on the frequency converter.
The new motor is registered.
4. Fit the front cover of the electrical compartment.
5. Print out the safety log (see section 7.2)
" The EPS 708 is ready for operation.
6.22 Replacing the pressure control valve
block
6.22.1 Removing the valve support
i Get a cloth ready for catching and mopping up
calibrating oil.
1. Turn off the EPS 708 at the master switch.
2. Secure the master switch so that it cannot be
switched back on.
3. Unplug the mains plug or disconnect from mains
electricity.
4. Open the protective hood.
458863-43_Ri
1
2
Fig. 86: Hose couplings
5. Disconnect the hoses from the hose couplings
(see Fig. 86, items 1 and 2).
6. Remove the cover of the hydraulics chamber.

Table of Contents