X7-8-Install-IG100 Installation Guide
Brocade
®
X7-8 Director Hardware Installation Guide
Checked? Data Notes
Output from supportshow command
Location of "spptshow.txt" file
Notes regarding supportshow output
Information about the new chassis
New factory serial number
New serial number (if available)
1. Open a telnet session and log on to the device as admin . The default password is password . Enable the logging
function on your telnet or serial console connection.
2. Back up the current configuration by entering the configupload -all . Enter the requested information at the
prompts.
NOTE
If you are using the Virtual Fabric feature, run configupload -vf before running the configupload
command to save the logical switch configuration.
This configUpload -all command uploads the device configuration to the customer-defined FTP server, making
it available for downloading. Alternatively, you can save the configuration file to a USB device. For more information
about this command, refer to the Brocade Fabric OS Command Reference Manual.
switch:admin> configupload
Protocol (scp or ftp) [ftp]: ftp
Server Name or IP Address [host]: 123.123.123.123
User Name [user]: Admin24
File Name [config.txt]: config-switch0.txt
Password:
Upload complete
switch:admin>
3. Record the WWN value: Enter wwn , and then copy the command output into a file named config-miscinfo.txt .
switch:admin> wwn
10:00:00:60:69:00:00:0a
4. Enter ipAddrShow , and then copy the command output into the config-miscinfo.txt file.
switch:admin> ipaddrshow
Chassis
Ethernet IP Address: 10.33.60.85
Ethernet Subnetmask: 255.255.240.0
CP0
Ethernet IP Address: 10.33.60.86
Ethernet Subnetmask: 255.255.240.0
Host Name: cp0
Gateway IP Address: 10.33.48.1
CP1
Ethernet IP Address: 10.33.60.87
Ethernet Subnetmask: 255.255.240.0
Host Name: cp1
Gateway IP Address: 10.33.48.1