LED Purpose Color Status Recommended Action
Fast-flashing green (on 1/4
second, then off 1/4 second)
Port is in internal loopback
(diagnostic).
No action is required.
Flickering green Port is online, with traffic flowing
through the port.
No action is required.
Steady amber Port is receiving light or signal
carrier, but it is not online yet.
Reset the port from
the workstation using
the portEnable or
portCfgPersistentEnable
command.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Port is disabled due
to diagnostic tests or
to portDisable or
portCfgPersistentEnable
commands.
Reset the port from
the workstation using
the portEnable or
portCfgPersistentEnable
commands.
Fast-flashing amber (on 1/2
second, then off 1/2 second)
A transceiver or port has an
error or is faulty.
Change the transceiver or reset
the switch from the workstation.
Alternating green and amber The port is bypassed. Reset the port from
the workstation using
the portEnable or
portCfgPersistentEnable
command.
Interpreting Control Processor Blade LEDs
See the following figure and table to interpret the LED patterns on the CPX7 blade. The LED patterns temporarily change
during POST and other diagnostic tests.
The following table describes the CP blade LED patterns and the recommended actions for those patterns.
X7-8-Install-IG100
81
Broadcom

Table of Contents

Related product manuals