Local CP state (slot number and CP ID), warm or cold, recovering or recovered.
•
Remote CP state (slot number and CP ID).
•
High Availability (enabled or disabled).
•
Heartbeat (up or down).
•
Health of standby CP.
•
HA synchronization status.
The following is an example of haShow output:
chassisX7:admin> hashow
Local CP (Slot 1, CP0): Active, Warm Recovered
Remote CP (Slot 2, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
Note the following about this output:
•
A warm recovery typically does not disrupt traffic flow.
•
A cold recovery is usually a result of a reboot of the active CP, which disrupts traffic.
•
A lack of HA synchronization can be related to a firmware download in progress or that the device is recovering from a
reboot or power-cycle.
historyShow
Use the historyShow command to display the entire history log, which includes insertion and removal events for field-
replaceable units (FRUs), such as blades, power supplies, fans, and world wide name (WWN) cards.
The following is an example of historyShow output:
chassisX7-8:admin> historyshow
CORE BLADE Slot 7 Inserted at Mon Jun 13 13:58:38 2016
Factory Part Number: 60-1003323-01
Factory Serial Number: DYH0339L00D
POWER SUPPLY Unit 1 Inserted at Mon Jun 13 13:59:09 2016
Factory Part Number: 23-0000163-01
Factory Serial Number: DUE2M03M04P
POWER SUPPLY Unit 2 Inserted at Mon Jun 13 13:59:09 2016
Factory Part Number: 23-0000161-01
Factory Serial Number: DUC2M35L0CL
POWER SUPPLY Unit 3 Inserted at Mon Jun 13 13:59:10 2016
Factory Part Number: 23-0000161-01
Factory Serial Number: DUC2M41L0JJ
POWER SUPPLY Unit 4 Inserted at Mon Jun 13 13:59:11 2016
Factory Part Number: 23-0000163-01
Factory Serial Number: DUE2M03M04S
SW BLADE Slot 3 Inserted at Mon Jun 13 13:59:12 2016
Factory Part Number: 60-1003336-01
Factory Serial Number: EAL0338L006
FAN Unit 1 Inserted at Mon Jun 13 13:59:13 2016