X7-8-Install-IG100 Installation Guide
Brocade
®
X7-8 Director Hardware Installation Guide
switchName: rsl8-st03-01
<output truncated>
switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
switch:admin>lscfg --show
Created switches: 128(ds) 1 2(bs)
Port 0 1 2 3 4 5 6 7 8 9
-------------------------------------------------------------------
FID 1 | 1 | 1 | 1 | 1 | 128 | 128 | 128 | 128 | 128 |
<output truncated>
switch:admin>
2. Determine any differences between the information in the SANafter.txt file and the information in the
SANbefor.txt file created earlier. In particular, look for differences in the following:
•
Device types
•
Number of devices
•
ISL and port states
•
Number of switches in the fabric
3. If an SCC policy exists on the active fabric where you are connecting the new chassis, modify the policy to include the
WWN of the new chassis.
•
Refer to the Brocade Fabric OS Administration Guide for information on SCC policy.
•
Use the wwn command to determine the WWN of the chassis.
•
Use the secPolicyAdd command to modify an existing policy.
4. Resolve any issues or unintentional changes to the device or fabric:
•
If there are any mechanical problems, try reseating the associated component.
•
If the configuration information is not correct for the device, modify as required.
•
If other issues exist, contact your support provider.
X7-8-Install-IG100