V-30
44 LIFE PERIOD
Replacement life of the periodical replacement parts can be set.
Note:
It is recommended to use the default value in normal use. Do not adjust these settings
without authorization.
Procedure
Description of Procedures LCD Message
1) Press the Continue button after selecting
Screen (a) “LIFE PERIOD” mode.
(a) → (b)
2) Using the Set or ▼ button, select the desired
code to be set and then press the Continue
button.
2: Fuser Cleaner (a) → (b)
7: OPC Belt Cartridge (d)
8: Fusing Unit (e)
9: 120K Replacement Kit (f)
3) Use the Set or ▼ button to select the desired
digit.
Use the Continue button to input a new value
to the selected (blinking) digit.
Upon completion of inputting the values to be
set, use the Set or ▼ button to select SET on
the LCD and then press the Continue button
to register the set value.
4) Press the Font button to complete the setting
work. (g)
5) Press the Font button one more time to
return to FACTORY MODE. (g) → (h)
39 FACTORY MODE
LIFE PERIOD SET
44 LIFE PERIOD
PERIOD FC ROLL
012000 P SET
a)
b)
c)
d)
e)
No.=<123456789>
PERIOD BC UNIT
05000 P SET
PERIOD FU UNIT
040000 P SET
39 FACTORY MODE
DP CHECK
h)
f)
PERIOD 120K UNIT
120000 P SET
44 LIFE PERIOD
g)
No.=<123456789>