V-37
46 NVRAM INITIAL
This mode can initialize (data clear) all the data in the NVRAM on the MCTL PCB.
CAUTION
BEFORE USING THIS MODE, THE VALUES FROM ‘34 TOTAL PAGES’ AND ‘35 EACH
IMAGE’ MUST BE READ TO ENABLE THE CORRECT VALUES TO BE RESET USING
FUNCTIONS 47 AND 48.
Note:
• Do not perform this mode other than when replacing the MCTL PCB.
• After performing this mode, be sure to set the LP TUNE UP value to ‘- 3’.
Description of Procedures LCD Message
1) Press the Continue button after selecting
Screen (a) “NVRAM INITIAL”.
(a)
→
(b)
2) Select YES if NVRAM INITIAL should be
executed. If not select NO.
Press the Continue button so that the RAM
INITIAL will be executed. (All the data will be
cleared.) (b)
→
(c)
3) For the RAM data setting information, refer to
Section 3.4.5 “Initial Setting of NVRAM” in
this chapter.
39 FACTORY MODE
NVM TUNE UP
46 NVRAM INITIAL
a)
b)
c)
YES / NO
39 FACTORY MODE
DP CHECK
47 TOTAL PAGE SET
This mode can reset the number of total pages in the NVRAM whenever NVRAM INITIAL
has been executed or the MCTL PCB is replaced.
Note: Do not perform this mode other than when replacing the MCTL PCB.
Description of Procedures LCD Message
1) Press the Continue button after selecting
Screen (a) “TOTAL PAGE SET”.
(a)
→
(b)
2) Use the Set or
▼
button to select the desired
digit.
Use the Shift button to input values to the
selected (blinking) digit.
Upon completing the input of the values, use
the Set or
▼
button to select SET displayed
on the LCD and then press the Continue
button to store the set value.
39 FACTORY MODE
TOTAL PAGE SET
47 TOTAL PAGE
a)
b)
c)
0 1 2 3 4 5 P SET
39 FACTORY MODE
DP CHECK