Confidential
2-12
Error
Code
Contents
Refer to
page:
2A00 No black ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2-32
2A01 No yellow ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2-32
2A02 No cyan ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2-32
2A03 No magenta ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2-32
2B00 Black ink cartridge ink remaining counter error 2-32
2B01 Yellow ink cartridge ink remaining counter error 2-32
2B02 Cyan ink cartridge ink remaining counter error 2-32
2B03 Magenta ink cartridge ink remaining counter error 2-32
2E00 Cannot communicate with ink cartridge IC chip (machine body side.) 2-33
2F00 Ink cartridge cover sensor detects opened cover state. 2-33
3000 Carriage does not move.
- Detected by the CR encoder sensor.
2-33
3100 Carriage cannot detect origin.
- Detected by the CR encoder sensor.
2-34
3200 Head capping is unable. 2-34
3500 Abnormal stop of head/carriage unit being driven
- Causes other than paper jam when ink is not discharging
2-35
3800 Abnormal stop of head/carriage unit being driven
- Caused by paper jam when ink is not discharging
2-35
3B00 Abnormal stop of head/carriage unit being driven
- Causes other than paper jam when ink is discharging
2-35
3C00 Abnormal stop of head/carriage unit being driven
- Caused by paper jam when ink is discharging
2-36
3E00 Defective occurs in the ASF motor, carriage motor or paper feed motor. 2-36
3F00 Carriage motor cannot stop. 2-37
4000 Casing internal thermistor defective
- Casing internal thermistor detects -20 degree-C or less, or 80 degree-C
or more when power is ON.
2-37
4200 Head voltage does not turn OFF. 2-37
4300 Head thermistor defective
- Head thermistor detects -20 degree-C or less, or 80 degree-C or more
when power is ON.
2-38
4400
Head driver IC detects abnormal temperature during operation or stand-by.
2-38
4600 Purge count or flushing count overflown. 2-38
4800 Head flat cable detected to be not correctly inserted. 2-38
4900 Head voltage does not raise. 2-39
4C00 ASIC thermistor error
- The ASIC thermistor detected a temperature of -21 degree-C or less, or
125 degree-C or greater, when the machine was turned on.
2-39