3 - 82
Main unit
Feed unit
8
X-sensor dog attachment
1. Attach the caution 1 to the X-carriage 2 with the 2 screws 1.
NOTE
The X sensor dog bends easily. Handle it carefully.
2. Bend the FFC (SML2CD-X) 3 90 degrees at a point 60 mm from the tip.
3. Attach the FFC (SML2CD-X) and the sheet 4 to X-carriage B with the
screw 2.
1
Torque
0.59 – 0.78 N-m
2
Torque
0.59 –
0.78 N-m
2
1 1 4 2
3
Bolt, Socket
M3X5
Color; Black
Screw, Bind
M3X4
Color; Silver