18
“HT4” CONTROL PANEL
To access the SPECIAL FUNCTIONS Menu (SET UP Fx) push the SPECIAL FUNCTIONS (FX) KEY.
WELDING MODE SELECTION LED
WELDING MODE SELECTION K
EY
WIRE KEY
ENCODER KNOB - A
PARAMETER SELECTION K
EY - A
PARAMETER SELECTION LED - A
PARAMETER DISPLAY S
CREEN - A
SPECIAL FUNCTIONS (FX) LED
SPECIAL FUNCTIONS (F
X) KEY
GAS KEY
ENCODER KNOB - V
PARAMETER SELECTION K
EY - V
PARAMETER SELECTION LED - V
PARAMETER DISPLAY S
CREEN - V
HOLD Function LED
PARAMETER DISPLAY SCREEN - A Displays the selected SPECIAL FUNCTION (Fx).
ENCODER K
NOB - A Used to select the various SPECIAL FUNCTIONS (Fx).
PARAMETER DISPLAY S
CREEN - V Displays the value for the selected SPECIAL FUNCTION (Fx).
ENCODER K
NOB - V Used to change the selected SPECIAL FUNCTION (Fx) value.
SPECIAL FUNCTIONS (F
X) KEY
Only enables entering and exit afterwards from the SPECIAL FUNCTIONS Menu (SET UP
Fx) on the HT4 panel and not on the DH panel.
SPECIAL FUNCTIONS (F
X) LED
The operator must press the SPECIAL FUNCTIONS (SET UP F
X) KEY for it to light up and be
included in the SPECIAL FUNCTIONS Menu (SET UP Fx).
The SPECIAL FUNCTIONS (Fx) related to the MIG dual pulse process correspond as follows to those on the wire feeder:
Special function
PARAMETER DISPLAY
Screen - A
PARAMETER DISPLAY Screen - V Welding mode
Default
Range
TWO STROKE (2T)
FOUR STROKE (4T)
CRATER 2T
CRATER 4T
SPOT WELDING
STITCH WELDING
CYCLE STANDARD
CYCLE ADVANCED
PRE GAS PrG 0.1s (0.0 - 2.0)s ●●●●●●●●
STARTING SPEED StS 0 -30 - +30 ●●●●●●●●
HOT START Hot 0 -30 - +30 ●●●●●●●●
STITCH TIME F05 1.0s (0.1 - 8.0)s
STITCH PAUSE F06 1.0s (0.1 - 8.0)s
SPOT TIME F07 3.0s (0.1 - 20.0)s
INITIAL CURRENT F08 20% -50% - +100% ●● ●●
INITIAL ARC LENGTH F09 0 -30 - +30 (*) (*) (*) (*)
INITIAL CRATER TIME F10 1.0s (0.0 - 5.0)s
INITIAL SLOPE F11 1.0s (0.0 - 5.0)s ●● ●●
FINAL SLOPE F12 1.0s (0.0 - 8.0)s ●● ●●
FINAL CURRENT F13 -30% -100% - +50% ●● ●●
FINAL ARC LENGTH F14 0 -30 - +30 (*) (*) (*) (*)