65
Error
condition
Error code Error description and possible diagnosis
Err E1.8
MIG DEFAULTS MISSING
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E1.9
WELDER DEFAULTS MISSING
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E2.0
FILE SYSTEM ERROR
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E3.2
STICKING
This error is displayed when a short-circuit has been formed between the machine’s output
terminals for more than 1.2 seconds.
NON automatic reset error.
To remove the error state, eliminate the short circuit so that the voltage on the torch goes above the
threshold value again. At this stage the error condition disappears and the welding machine goes
back to the mode prior to the sticking. If the torch trigger is still pushed, it must be released and
pressed again to begin welding again.
Err E3.3
MOTOR SPEED FAULT
NON automatic reset error.
Check that the rollers on the wire feeder mechanism are not stuck and that the welding wire comes
out correctly, otherwise contact Technical Assistance Department immediately.
Err E4.0
LAST SETUP NOT VALID
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E4.1
JOBS WRONG
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E4.2
MIG SYN SPECIAL FUNCTION (Fx) WRONG
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E4.3
MIG MAN SPECIAL FUNCTION (Fx) WRONG
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E4.4
SPECIAL PULSED MIG FUNCTIONS (Fx) NOT VALID
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E4.5
SPECIAL DOUBLE PULSED MIG FUNCTIONS (Fx) NOT VALID
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E5.0
MIG PROGRAMS MISSING
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E5.1
PULSED MIG WELDING PROGRAMMES MISSING
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
Err E5.3
MMA PROGRAMS MISSING
NON automatic reset error.
Immediately contact technical assistance dept.
Error visible on VISION S
CREEN ONLY in the event of a fault and NOT in the ERROR LOG Menu.
(continued)