Loading...
Installing the 6200 network element 5-31
6200 Packet-Optical Platform Installation, Commissioning, and Testing Procedures
Release 1.1 009-6200-201 Draft Issue 1
Copyright
©
2014 Ciena
®
Corporation September 2014
Procedure 5-8
Connecting fiber optic cables to STM-1/4/16 or
OC-3/12/48 interfaces on 2.5G MRO card
Use this procedure to connect the fiber optic cables to the
STM-1/4/16/OC-3/12/48 interfaces of the 6200 network element.
Prerequisites
Make sure that the following tools and materials are available:
four simplex LC optical patch cords or two duplex LC optical patch cords
cable ties
Ensure that the SFP modules are inserted into the STM-1/4/16/OC-3/12/48
interface ports, refer to Procedure 10-6, Installing and removing pluggable
modules for details.
CAUTION
Risk of equipment damage
Electrostatic discharge can damage electrostatic sensitive
devices. Use antistatic protection to avoid damaging the shelf
and circuit packs.
DANGER
Risk of personal injury
When the shelf is powered on, the optical interface ports emit
laser light that can blind. Keep all optical connectors on the
optical interface ports capped when they are not connected to
optical fiber cables. Never look directly into the end of an
optical fiber.