7-54 System testing
6200 Packet-Optical Platform Installation, Commissioning, and Testing Procedures
Release 1.1 009-6200-201 Draft Issue 1
Copyright
©
2014 Ciena
®
Corporation September 2014
Procedure 7-12
Testing Ethernet parameter retrieval using SNMP
Use this procedure to perform the following tests on the 6200 network
element:
Test Ethernet parameter retrieval using SNMP.
Prerequisites
A MIB browser like iReasoning. This is available for free download at the
following location, http://ireasoning.com/mibbrowser.shtml
A standalone network element which has any Ethernet circuit pack
(transport or switching circuit pack).
CAUTION
Risk of damage to circuit packs
Electrostatic discharge can damage electrostatic
sensitive devices. Ensure that you are wearing the
antistatic strap connected to the ESD location on the
6200 network element.
DANGER
Risk of eye injury
Avoid direct exposure to laser beam or fiber. Invisible
light can blind. Keep all unused optical connectors
capped.