SERVICE MANUAL Post eVolve Smart
12 - ERRORS AND TROUBLESHOOTING
CIRCONTROL, S.A. Innovació, 3 08232 Viladecavalls (Barcelona)
Tel.: +34 937 362 940 Fax: +34 937 362 941 76
Web: www.circontrol.com E-mail: circontrol@circontrol.com
12.2 OCPP 1.5 COMMON ERRORS
CONCEPT
After applying new settings, please go to next URL from Charge Point in order to check
the proper connection of the integration chosen:
http://<IP>/services/cpi/log?app=ocpp1.5
Look especially for the following messages:
If ‘CB boot notification: success’ appears when the Charge Point is properly
connected to the Central System.
Otherwise, if the message shown is ‘Registering CB in the CS: failed’ then check
following list of errors:
12.2.1 Connect failed in tcp_connect
Example:
Sep 7 08:55:15
(none)
user.err
ocpp1.5: OcppCsEngine.cpp:254 - Registering CB in the CS: failed
Sep 7 08:55:15
(none)
user.err
ocpp1.5: OcppCsClient.cpp:197 - Notifying Boot - 28, SOAP-
ENV:Sender, , , connect failed in tcp_connect()
Common causes:
The host URL introduced is not correct. Check it on the OCPP configuration.
Check if embedded modem is connected to the network. Otherwise check
modem parameters (some cellular providers require special APN
configuration).
If there is no modem. Then ethernet IP address shall be static, using gateway
and DNS from this network. Do not use DHCP=ON