EasyManua.ls Logo

Cisco MWR 2941 - Page 167

Cisco MWR 2941
708 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cisco MWR 2941 Router Command Reference, Release 15.0(1)MR
ethernet oam link-monitor frame-seconds
149
Cisco MWR 2941 Router Command Reference, Release 15.0(1)MR
OL-23890-01
Examples The following example shows how to configure an Ethernet OAM link-monitor frame-seconds window
of 30000 milliseconds (30 seconds):
Router(config-template)# ethernet oam link-monitor frame-seconds window 300
Related Commands ethernet oam link-monitor
frame
Configures an error frame threshold or window on an Ethernet OAM
interface.
ethernet oam link-monitor
frame-period
Configures an error frame period on an Ethernet OAM interface.
ethernet oam link-monitor
high-threshold action
Configures a specific action to occur when a high threshold for an
error is exceeded on an Ethernet OAM interface.
ethernet oam link-monitor
receive-crc
Configures an Ethernet OAM interface to monitor frames received
with CRC errors for a period of time.
ethernet oam link-monitor
symbol-period
Configures an error symbol period on an Ethernet OAM interface.
ethernet oam link-monitor
transmit-crc
Configures an Ethernet OAM interface to monitor frames transmitted
with CRC errors for a period of time.

Table of Contents