A-20
Cisco ONS 15454 Reference Manual, R7.0.1
OL-9217-01
Appendix A Hardware Specifications
A.5 A.5.5 DS3-12 and DS3N-12 Card Specifications
Depth: 9.000 in. (228.6 mm)
Weight: 1.7 lb (0.7 kg)
A.5.5 DS3-12 and DS3N-12 Card Specifications
The DS3-12 and DS3N-12 cards have the following specifications:
Input
Bit rate: 44.736 Mbps +/– 20 ppm
Frame format: DS-3 ANSI T1.107-1988
Line code: B3ZS
Termination: Unbalanced coaxial cable
Input impedance: 75 ohms +/–5 percent
Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179
AIS: TR-TSY-000191 compliant
Output
Bit rate: 44.736 Mbps +/– 20 ppm
Frame format: DS-3 ANSI T1.107-1988
Line code: B3ZS
Termination: Unbalanced coaxial cable
Input impedance: 75 ohms +/–5 percent
Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179
AIS: TR-TSY-000191 compliant
Power level: –1.8 to +5.7 dBm
Pulse shape: ANSI T1.102-1988 Figure 8
Pulse amplitude: 0.36 to 0.85 V peak-to-peak
Loopback modes: Terminal and facility
Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)
Electrical interface: BNC or SMB connectors
Surge protection: Telcordia GR-1089
Operating temperature
C-Temp (15454-DS3-12 and 15454-DS3N-12): 0 to 131 degrees Fahrenheit (0 to
+55 degrees Celsius)
I-Temp (15454-DS3-12-T and 15454-DS3N-12-T): –40 to 149 degrees Fahrenheit (–40 to
+65 degrees Celsius)
Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card
without this symbol is C-Temp compliant.
Operating humidity: 5 to 95 percent, noncondensing